GP102 Overload System

Product Highlights

The GP102 control module provides a failsafe cutout signal to prevent operation of a scissor vehicle when its platform is overloaded.

In combination with sensors to measure platform height and lift cylinder load, the card is programmed for no-load and full-load conditions and subsequently calculates an estimate of load. Programming and other set-up & configuration activities are carried out using the hand-held “EZcal” device.

An integral tilt transducer can optionally be configured to provide additional vehicle cutout functions.

  • Provides cutout signal when platform overloaded (per EN 280 5.4.1.2a) using Load and angle transducers (EZfit)
  • Configurable lamp & alarm output (per EN 280 5.4.1.2b)
  • Integral vehicle tilt transducer, indicates tilted vehicle (per EN 280 5.3.2) with optional cutout
  • Optional Armguard cutout (per EN 280 5.4.4)
  • Interlocks (subject to installation, per EN 280 5.4.1.2c and EN 280 5.7.7)

Technical Data:

Power Supply rated for 8.5 to 32VDC 12/24V
Failsafe High Side Cutout Output,
protected, 2.5A
1
High Side Indicator Outputs, .7A 3
Integral Tilt Sensor ± 0 to 10°
Digital Inputs 10
Analog Inputs 4
Negative Digital Inputs 3
Sealing IP67
Operating Temperature -40 + 60° C
Overall Dimensions, L x W x H 7.3” x 4.5” x 1.5”
185 x 115 x 39 mm